Technical Notes, White paper and presentation on LTE, GSM, GPRS, EDGE and CDMA network, 3GPP specifications, UTRAN, GERAN and non 3GPP wireless concepts. This blog also covers programming concepts like C and C++, Embedded programming, SNMP Framework, NMS/EMS, Provisioning system, small cell concepts
Monday, February 24, 2014
Inter-frequency Hard Handover Events in Small Cells
During the hard handover procedure for inter-frequency, when the UE is moving away from HNB coverage area, HNB will receive the event 2D when quality of the currently used frequency is below the 2D threshold configured. When the event 2D is triggered, compressed mode scanning will be started. If the UE moves further away and satisfy the event 2B condition when estimated quality of the currently used frequency is below the 2B threshold configured and estimated quality of the non-used frequency is above the configured threshold. Event 2B will trigger the handover procedure.
However if the Event 2D threshold is met and compressed mode measurement reporting is started but UE is moving towards the HNB coverage area and the estimated quality of the currently used frequency is better than the configured 2F threshold, UE will exit the compressed mode.
Subscribe to: